Part Number Hot Search : 
258BT 74HC45 2SC3151 2SC20 105K2 PC922 TDA7253L 60001
Product Description
Full Text Search
 

To Download E3X-A11 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  2 e3x e3x 2 fiber-optic photoelectric sensor e3x high performance amplifier has fast response time, longer sensing distance and self-diagnostic functions ordering information use e32-series fiber-optic cables. refer to e32 data sheet in this catalog for specifications. fiber-optic cables high gain amplifiers part number npn output e3x-h11 type high sensitivity self diagnostic function none off-delay timer provided light source red led part number npn output E3X-A11 e3x-a21 e3x-f21 e3x-vg11 e3x-vg21 pnp output e3x-a41 e3x-a51 e3x-f51 type general-purpose high-speed mark sensing self-diagnostic function none provided provided none provided off-delay timer none provided provided none provided light source red led green led amplifiers note: neither cover has any printing, such as part number, voltage or wiring information. accessories description part number cover with adjustment knob clear cover with gray knob allows sensitivity adjustment without e39-g3 removing cover. enclosure rating is reduced to ip50. replacement cover smoked gray plastic like original cover e39-g4 ultra fast 20 sec. response time (e3x-f) extended sensing distance (e3x-h) user friendly features: - 8-turn sensitivity with position indicator - ip66 enclosure rating - slim body mounts on din rail set-mode blinking light source aids alignment
3 e3x e3x 3 part number npn E3X-A11 e3x-a21 e3x-f21 e3x-vg11 e3x-vg21 pnp e3x-a41 e3x-a51 e3x-f51 supply voltage 10-30 vdc 12-24 vdc 10% 10-30 vdc 10% ripple max. 10% ripple max. 10% ripple max. current consumption 35 ma max. 40 ma max. required fiber optic cables all e32-series light source pulse-modulated red led (660 nm) pulse-modulated green led (565 nm) operation mode light-on, dark-on or set modes (switch selectable) sensitivity 8-turn potentiometer with clutch and indicator mutual interference protection not provided control type npn open collector pnp open collector max. load 100 ma, 30 vdc max. 100 ma, 40 vdc max. max. on-state 1 vdc max. at 100 ma voltage drop response time 200 s max. on: 20 s max. 200 s max. off: 30 s max. timing functions off-delay, off-delay, 0.01 to 0.1 sec, 0.01 to 0.1 sec, adjustable; adjustable; switch selectable switch selectable alarm output 50 ma, 50 ma, 30 vdc max. 40 vdc max. check input input voltage light off: light off: 1.5 v max. 1.5 v max. circuit protection output short circuit protection, dc power reverse polarity protection indicators light received (red led) and output stability (green led) materials case heat-resistant abs cover polycarbonate mounting din rail track, or on flat surface through holes in bracket (provided) connections prewired 3 conductor 5 conductor 3 conductor 5 conductor cable, cable, cable, cable, 2 m (6.5 ft) 2 m (6.5 ft) 2 m (6.5 ft) 2 m (6.5 ft) weight 100 g (3.5 oz.) with 2 m cable enclosure rating iec ip66 (with cover on) ambient operating -25 to 55 c with no ice buildup (-13 to 131 f) temperature storage -40 to 70 c (-40 to 158 f) specifications output dc solid- state
4 e3x e3x 4 high gain amplifier part number e3x-h11 supply voltage 10 - 30 vdc 10% ripple max. current consumption 35 ma max. required fiber optic cables all e32 series light source pulse modulated red led (660 nm) operation mode light on, dark on sensitivity 8 turn potentiometer control type npn - open collector max. load 100 ma, 30 vdc max. on-state 1 vdc max. at 100 ma voltage drop response time 1 m sec max. timing functions off delay 40 ms fixed switch selectable circuit protection output short-circuit protection, dc power reverse polarity protection indicators light received (red led) and output stability (green led) materials case heat resistant abs cover polycarbonate mounting din rail track, or on flat surface through holes in bracket (provided) connections prewired 3 conductor cable 2 m (6.5 ft) weight 100g (3.5 oz) with 2 m cable enclosure ratings iec ip66 (with cover on) ambient temperature operating -25 to -55 c with no icing build-up (-13 to 131 f) storage -40 to 70 c (-40 to 158 f) output dc solid- state
5 e3x e3x 5 note: set the mode selector to l-on or d-on after the light axis is adjusted. stable operation indicator (green indicator) sensitivity indicator the position of the indicator can be checked. 8-turn sensitivity adjuster e3x-h11 mode selector set: the light source flashes. set to this mode to adjust the light axis. l-on: output transistor is on when light is received. d-on: output transistor is on when light is not received. light reception indicator (red indicator) hysteresis adjuster timer switch on: timer function is on. off: timer function is off. e3x-a21/-a51 e3x-f21/-f51 e3x-vg21 E3X-A11/-a41 e3x-vg11 light reception indicator (red indicator) sensitivity indicator sensitivity adjustment can be checked visually. stable operation indicator (green indicator) 8-turn sensitivity adjuster nomenclature mode selector set: the light source flashes. set to this mode to adjust the light axis. l-on: output transistor is on when light is received. d-on: output transistor is on when light is not received. light reception monitoring terminal monitoring is used with the e39-vx beam checker light reception monitoring terminal monitoring is used with the e39-vx beam checker mode selector set: the light source flashes. set to this mode to adjust the light axis. l-on: output transistor is on when light is received. d-on: output transistor is on when light is not received. light reception monitoring terminal monitoring is used with the e39-vx beam checker stable operation indicator (green indicator) sensitivity indicator timer sensitivity adjuster light reception indicator (red indicator) timer switch on: timer function is on. off: timer function is off.
6 e3x e3x 6 type model mode output output circuit switch transistor npn e3x-h11 light on on when light E3X-A11 is received. e3x-vg11 dark on on when light is not received. e3x-a21 light on on when light e3x-vg21 is received. e3x-f21 dark on on when light is not received. pnp e3x-a41 light on on when light is received. dark on on when light is not received. e3x-a51 light on on when light e3x-f51 is received. dark on on when light is not received. output circuits light (red) stability (green) black brown load blue z d z d : v z = 39 v 100 ma max. light (red) stability (green) orange main circuit brown load (relay) blue z z d (zener diode): v z = 39 v self- diagnosis output pink load (relay) control output external- check input z 10 k light (red) stability (green) main circuit blue z d : v z = 39 v black z d brown 100 ma max. load light (red) stability (green) main circuit blue z d (zener diode): v z = 39 v black z brown control output load (relay) pink 10 k z external- check input orange load (relay) self-diagnosis output main circuit black operation
7 e3x e3x 7 type model mode output timing circuit switch transistor npn e3x-h11 light on on when light E3X-A11 is received. e3x-vg11 dark on on when light is not received. e3x-a21 light on on when light e3x-vg21 is received. e3x-f21 dark on on when light is not received. light received light not received light indicator (red) output transistor load (relay) on off on off operate release (between brown and black) (between brown and black) (between brown and black) (between brown and black) timing charts light received light not received light indicator (red) output transistor load (relay) on off on off operate release light received light not received light indicator (red) output transistor load (relay) on off on off operate release t light received light not received light indicator (red) output transistor load (relay) on off on off operate release t
8 e3x e3x 8 type model mode output timing chart switch transistor pnp e3x-a41 light on on when light is received. dark on on when light is not received. e3x-a51 light on on when light e3x-f51 is received. dark on on when light is not received. (between blue and black) (between blue and black) (between blue and black) (between blue and black) light received light not received light indicator (red) output transistor load (relay) on off on off operate release light received light not received light indicator (red) output transistor load (relay) on off on off operate release light received light not received light indicator (red) output transistor load (relay) on off on off operate release light received light not received light indicator (red) output transistor load (relay) on off on off operate release t t
9 e3x e3x 9 sensing method detection light indicators through-beam off on reflective detection on off detection of the on difference in color or shade off retroreflective off on detection ?ith sensing object?1 note: 1. if the indicators operate as described in the table, the e3x can operate in stable condition within the rated temperature ra nge. 2. even when the green indicator is off, the e3x will operate stably if the operating temperature change since the initial settings is within 10 c. using a sensing object, set the sensitivity adjust so that the indicators operate as described in the following table: green: light on red: light off green: light on red: light on green: light on red: light off green: light on red: light on green: light on red: light on green: light on red: light off green: light on red: light off green: light on red: light on reflecting plate with sensing object detection with/o sensing object 1 without sensing object detection single with sensing object 1 detection without sensing object 2 detection color high reflection 3 detection color low reflection 3 detection with sensing object 4 without sensing object with sensing object without sensing object color that has a low reflective ratio color that has a high reflective ratio with sensing object reflecting plate adjusting sensitivity e3x-h11/-a ?? /-f ?? /-vg ??
10 e3x e3x 10 light axis adjustment with flashing function e3x-a ?? /-f ?? /-vg ?? stable operation indicator (green indicator) with this function, the e3x checks changes in environment conditions (especially a change in the ambient temperature) and self-diagnoses the resistance against the changes. the result is shown by the indicators or an output signal. improper light axis 2. adjust the light axis by moving the fiber with the light flashing. proper light axis 3. set the mode selector to l-on or d-on after the light axis is adjusted. mode selector flashing light axis adjusted light on with no flashing self-diagnostic function light reception indicator (red indicator) displays stable operation indicator: changes in environmental conditions (changes in the ambient temperature, the operating voltage, or the volume of dust) are checked and the resistance against them are self-diagnosed. the result is shown via the indicator. light reception indicator: the amount of light received is shown by this indicator. output: the resistance against changes in environmental conditions is shown by the indicator and the result is output. 1. set the mode selector to set. *if the self-diagnostic output is on when the sensing object is moving at low speed, use the e3x with an on-delay timer circuit. tip of the fiber connected to the light source side in the set mode flashing flashing 0.3 s min. 0.3 s min. on off on off control output (l, on) self-diagnostic output* indicator operating level x 1.2 operating level operating level x 0.8 amount of light 1.2 1 0.8 red green green light on green
11 e3x e3x 11 variable hysteresis function (e3x-h11) detection of plate level differences min max min max min max (if detection is impossible with the hysteresis value set to maximum) refer to the following when using the hysteresis adjuster. detecting operation is not stable because zone b is within the hysteresis differential range. reduce the sensitivity of the e3x with the sensitivity adjuster and turn off zone b. reduce the hysteresis value with the hysteresis adjuster so that zone a will be on. reflection of light reflection of light reflection of light large hysteresis differential small hysteresis differential on on on off off a on b off a unstable b unstable b off a on off set both the sensitivity adjuster and hysteresis adjuster to maximum. decide the position of the fiber head and that of the sensing object in zone a. locate the head in zone a and turn the sensitivity adjuster counterclockwise slowly until the stable operation indicator and light reception indicator are off (i.e., position e as shown in the illustration). detection is possible when the head is located in zone b, light reception indicator is lit. set the hysteresis adjuster to the point where the light reception indicator is lit (i.e., position e as shown in the illustration.) a b (example) min max sens 1 s sensitivity adjuster hysteresis differential adjuster min max no sl locate the head in zone a and turn the sensitivity adjuster counterclockwise until the light reception indicator and stable operation indicator are off (i.e., position o as shown in the illustration). yes sl yes sl locate the head in zone b and turn the hysteresis adjuster counterclockwise slowly and make sure that the light reception indicator is lit. yes sl the light reception indicator is lit when the head is located in zone b and the light reception indicator is off when the head is located in zone a. (h) min max sens 1 s (e) locate the head in zone a and turn the sensitivity adjuster clockwise until the stable operation indicator and light reception indicator are off (i.e., position f as shown in the illustration.) set the hysteresis adjuster to maximum. min max sens 1 s (g) (f) min max sens 1 s (g) (e) no sl no sl
12 e3x e3x 12 external diagnostic input function with this function, light projection can be stopped when desired. the operation of the sensor can be checked with this function before the e3x is placed into actual operation. e3x-f ?? /-vg ?? e3x-a ?? light is emitted from the projection fiber head when the self- diagnostic inputs is on. the sensor, however, will not operate. npn type no light is emitted from the projection fiber head when self- diagnostic input is on. special fiber units the following special accessories are available (order separately). contact your omron representative for the details. light projection stops brown (+v) brown (+v) brown (+v) brown (+v) blue (0 v) blue (0 v) blue (0 v) blue (0 v) light pnp type light projection stops light off off on on pink (external- check input) pink (external- check input) pink (external- check input) pink (external- check input) fiber units with special length of stainless steel tube fiber with different lengths of stainless steel tubes are available. applicable models e32-tc200f (tube with 0.9 dia.) e32-tc200b/dc200f (tube with 1.2 dia.) e32-dc200b (tube with 2.5 dia.) appearance the length can be ordered in increments of 10 mm between 10 mm min. and 120 mm max. tolerance: 1.0 mm if l is 40 mm or less and 2.0 if l is more than 40 mm. (note that standard fiber units have a 90-mm or 40-mm long stainless steel tube.) external-diagnostic input (between blue and pink) short open on off on off led for light projection indicator by short-circuiting the brown and pink cords, light projection can be stopped (with a short-circuit current of 0.2 ma max.). l by short-circuiting the pink and blue cords, light projection can be stopped (with a short-circuit current of 0.2 ma max.). external-diagnostic input (between blue and pink) short open on off on off led for light projection indicator
13 e3x e3x 13 sensing distance for tubes with 90 bends applicable models e32-tc200b/tc200f/dc200f the length overall is 120 mm max. note: if larger l 1 is required, use the e39-f11 sleeve bender. fiber units with 90 bend in stainless steel tube appearance stainless steel tube with a 90 bend at the tip stainless steel tube with a 90 bend at the base bending radius l 1 ( 1) r 5.0 10.0 mm 15.0 mm r 7.5 12.5 mm 17.5 mm r 10.0 15.0 mm 20.0 mm r 12.5 17.5 mm 22.5 mm bending radius l 2 ( 1) r 5.0 5.0 mm 10.0 mm r 7.5 7.5 mm 17.5 mm r 10.0 10.0 mm 20.0 mm r 12.5 12.5 mm 22.5 mm the length overall is 120 mm max. note: if larger l 2 is required, use the e39-f11 sleeve bender. model amplifier bending radius standard r 5.0 r 7.5 r 10.0 r 12.5 e32-tc200b e3x-h11 400 mm 260 mm 330 mm 360 mm 400 mm e3x-a ?? 180 mm 110 mm 140 mm 160 mm 180 mm e32-tc200f e3x-h11 100 mm 55 mm 100 mm 100 mm 100 mm e3x-a ?? 50 mm 30 mm 50 mm 50 mm 50 mm e32-dc200f e3x-h11 36 mm 30 mm 36 mm 36 mm 36 mm e3x-a ?? 18 mm 10 mm 18 mm 18 mm 18 mm fiber unit with longer fiber applicable models e32-tc200/-dc200 e32-tc200b/-dc200b e32-tc200e/-dc200e e32-tc200f/-dc200f e32-tc200a appearance the length can be ordered in increments of 1 m between 6 m min. and 20 m max. (2 m and 5 m fiber length types are standard for e32-tc200, e32-dc200.) length r length r l length 1 2
14 e3x e3x 14 e3x-a ?? , e32-tc200 (typical) fiber length vs. sensing distance through-beam fiber unit (based on the sensing distance using a fiber length of 2 m as 100%) reflective fiber unit (based on the sensing distance using a fiber length of 2 m as 100%) e3x-a ?? , e32-dc200 (typical) fiber length (m) fiber length (m) 100 80 60 40 0 25 10 20 20 30 40 sensing distance (%) 100 80 60 40 0 25 10 20 20 15 sensing distance (%) 200 160 120 80 0 25 10 20 40 30 40 sensing distance (mm) fiber length (m) fiber length (m) 100 80 60 40 0 2 5 10 20 15 20 sensing distance (mm) e3x-h11 e3x-a ?? e3x-f ?? e3x-vg ?? cable: 2-m polyvinyl chloride-covered cable (4-mm dia., 5 cores*) weight: approx. 100 g *the cables for the E3X-A11, e3x-a41, and e3x-vg11 models have 3 cores. light reception indicator 15.8 stable operation indicator 59 4 30 25 22.5 13 8.4 8 two, 2.4 dia. 12.5 3.9 3.2 dia. 37 16 3.4 22.5 2 16 amplifier mounting bracket (removable) 6 9 6 dimensions unit: mm (inch)
15 e3x e3x 15 reflector (small) e39-r3 reflector note: mounting bracket is attached. 34.8 19.3 two, m3 2.6 1.2 20 0.2 11 adhesive tape reflector e39-r1 installation connections power supply voltage output functions npn input pnp input 100 to 240 vac relay and, or s3d2-ak-us s3d2-akb-us and, or, and timer s3d2-ck-us s3d2-ckb-us flip-flop s3d2-bk-us --- transistor and, or, and timer s3d2-cc-us s3d2-ccb-us connection with s3d2 sensor controller connection with s3d8 sensor controller note: a maximum of two e3x optical fiber photoelectric sensors can be connected. note: a maximum of eight e3x optical fiber photoelectric sensors can be connected. black blue 0 v brown +12 v in 1 blue black brown +12 v 0 v 12 11 10 9 8 7 in 1 in 2 norm inv 4 56 1 2 3 7.5 40.3 34 7 two 3.5 dia. 59.9 52 1.6 8 2.7 25.4 34 38 unit: mm (inch)
16 e3x e3x 16 tightening force the tightening force applied to the fiber unit should be as follows: precautions fiber units screw-mounting model use a proper-sized spanner. nuts (attachment) toothed washers retaining screw (m 3 max.) clamping torque 3 kgf ? cm max. column model fiber connection and disconnection the e3x amplifier has a lever lock. connect or disconnect the fibers to or from the e3x amplifier using the following procedures: fiber units clamping torque m3/m4 screw 8 kgf ? cm max. (0.78 n ? m) m6 screw 10 kgf ? cm max. (0.98 n ? m) 2-mm dia. column 3 kgf ? cm max. (0.29 n ? m) 3-mm dia. column 3 kgf ? cm max. (0.29 n ? m) e32-d14l 10 kgf ? cm max. (0.98 n ? m) e32-t12f 8 kgf ? cm max. (0.78 n ? m) e32-d12f 8 kgf ? cm max. (0.78 n ? m) e32-t16 5 kgf ? cm max. (0.49 n ? m) e32-r21 6 kgf ? cm max. (0.59 n ? m) e32-m21 up to 5 mm to the tip: 5 kgf ? cm max. (0.49 n ? m) up to 5 mm from the tip: 8 kgf ? cm max. (0.78 n ? m) e32-l25a 8 kgf ? cm max. (0.78 n ? m) spring mounting clip 1. connection insertion mark fiber insert the fibers into the e3x amplifier and press the lever lock until the amplifier clicks to lock the fibers. the fibers will have insertion marks when they are cut with the e39-f4 (fiber cutter). the portion from the tips to the insertion mark should be inserted to the e3x. 2. disconnection raise the lock lever to unlock the fibers before pulling them out. fiber insertion if the portion from the tip to the insertion mark of the fibers are not inserted into the amplifier unit, the sensing distance will be reduced. lever lock locked unlocked
17 e3x e3x 17 correct connection do not pull or press the fiber units. the fiber units have a withstand force of 1 kg or 3 kg (pay utmost attention because the fibers are thin). do not bend the fiber units beyond the permissible bending radius. do not bend the edge of the fiber units. incorrect do not apply excess force on the fiber units. 40 mm max. amplifier fiber unit 20 mm max. fiber unit nylon wireholder metal holder the fiber head could be broken by excessive vibration. to prevent this, the following is effective: a one-turn loop can absorb vibrations tape mounting 1. mount the front part on the mounting bracket (sold together) or a din rail. 2. press the back part onto the mounting bracket or the din rail. removal by pulling back the lock (yellow) on the bottom with a flat blade screwdriver, the amplifier can be removed with ease. in the case of side mounting, attach the mounting bracket on the amplifier first, and secure the amplifier with m3 screws and washers. the diameter of the washers should be 6 mm max. others when power is off: the moment power is turned off, the e3x could output a pulse signal which could affect the operation of the devices connected to it. this will happen more often if power is supplied to the e3x from an external power supply, thus affecting the connected timer and counter. use a built-in power supply as much as possible to avoid this. if power is supplied to a photoelectric sensor through a cord that is wired together with other power lines in the same duct, the cord will be influenced by the power lines and malfunctioning of the photoelectric sensor or damage could result. wire the cord separately or use a sealed cord to supply power to the photoelectric sensor. if the case of the cord is extended, use a wire with 0.3 mm 2 max.. the total length of the cord should be 100 m max. power supply: if a standard switching regulator is used as a power supply, the frame ground (fg) terminal and the ground (g) terminal must be grounded, or otherwise the e3x can malfunction, influenced by the switching noise of the power supply. the supplied voltage must be within the rated voltage range. unregulated full- or half-wave rectifiers must not be used as power supplies. do not use a hammer to hit the amplifier when mounting or the amplifier will loose watertightness. amplifier units correct incorrect power line din rail washers (6 dia. max.)
18 e3x e3x omron electronics llc omron canada, inc. one east commerce drive 885 milner avenue schaumburg, il 60173 scarborough, ontario m1b 5v8 1-800-55-omron 416-286-6465 cat. no. cedsax4 11/01 specifications subject to change without notice. printed in the u.s.a. omron on-line global - http://www.omron.com usa - http://www.omron.com/oei canada - http://www.omron.com/oci


▲Up To Search▲   

 
Price & Availability of E3X-A11

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X